Godavari TransCare & Partner logoGODAVARI TRANSCARE& PARTNER · Pune

All our services

38 services across five categories — transformer, testing, HT/LT, earthing and oil filtration.

Oil filtration and testing on site
SERVICESSERVICE PLATE
Service finder

Search every service

Type a keyword or filter by category.

38 SERVICES

Oil FiltrationTransformer Oil Filtration ServiceOn-site vacuum filtration to remove moisture, gases, sludge and particles from transformer oil.Oil FiltrationBefore & After BDV TestingBreakdown voltage measured before and after filtration and shared with you.Oil FiltrationTransformer Oil Top-UpTopping up with suitable transformer oil to bring the level back to normal.Oil FiltrationOil Filtration Machine Rental & SupplyFiltration machine available on rent or for supply, for plants with their own teams.Oil FiltrationTransformer Oil Lab TestingMoisture, acidity, BDV and DGA tests to decide what the oil really needs.Transformer ServicesTransformer Preventive MaintenanceScheduled checks of oil, bushings, gaskets, breather, connections and protection.Transformer ServicesOLTC Inspection & ServicingInspection, cleaning and servicing of on-load tap changers for smooth operation.Transformer ServicesTransformer Oil Leakage RepairLocating and stopping oil leaks from gaskets, valves and welds.Transformer ServicesTransformer Gasket ReplacementReplacing hardened or damaged gaskets to keep the tank sealed.Transformer ServicesTransformer Bushing ReplacementReplacing cracked or damaged HT/LT bushings.Transformer ServicesTransformer Internal Inspection & RepairInternal inspection and repair of core, windings and connections.Transformer ServicesTransformer RewindingRewinding of damaged windings to restore the transformer.Transformer ServicesTransformer Installation & UninstallationSafe installation, shifting and removal of transformers.Transformer ServicesTransformer Testing & CommissioningPre-commissioning tests and safe charging of new or repaired transformers.Transformer ServicesTransformer Oil Top-UpBringing the oil level back to normal with suitable oil.Transformer ServicesSilica Gel ReplacementReplacing saturated silica gel in the breather to keep moisture out.Transformer ServicesTransformer Breakdown MaintenanceQuick response to transformer faults and breakdowns.Testing & Oil LabInsulation Resistance (IR) TestingChecks the condition of insulation between windings and to earth.Testing & Oil LabEarth Resistance TestingMeasures the resistance of earth pits and earthing systems.Testing & Oil LabTransformer Voltage Ratio TestingConfirms the turns ratio across taps to detect winding faults.Testing & Oil LabMagnetic Balance TestingChecks the balance of the magnetic circuit between phases.Testing & Oil LabWinding Resistance TestingDetects loose connections, broken strands and tap-changer contact problems.Testing & Oil LabElectrical Equipment InspectionInspection of transformers, panels and equipment with a clear report.Testing & Oil LabTransformer Oil Lab TestingBDV, moisture content, DGA, acidity, particle analysis and furan & DDF tests.HT/LT & SubstationHT Panel MaintenanceCleaning, tightening, inspection and testing of HT panels.HT/LT & SubstationLT Panel MaintenanceMaintenance of LT panels, busbars, connections and protection devices.HT/LT & SubstationHT/LT Breaker ServicingServicing and testing of HT/LT breakers for reliable operation.HT/LT & SubstationVCB Maintenance & ServicingVacuum circuit breaker inspection, servicing and operational checks.HT/LT & SubstationLT/HT Bushing Gasket ReplacementReplacing worn bushing gaskets to stop leaks and moisture entry.HT/LT & SubstationSubstation Installation & MaintenanceInstallation and upkeep of substations and their equipment.HT/LT & SubstationHT/LT Electrical Maintenance & AMCAnnual maintenance contracts for panels, breakers and transformers.HT/LT & SubstationElectrical Breakdown ServicesFast response to electrical faults and breakdowns.Earthing & LightningIndustrial EarthingFactory and machine earthing for safe operation of equipment.Earthing & LightningSubstation EarthingTransformer and grid earthing for substations.Earthing & LightningHome EarthingHouse and inverter earthing for safer homes.Earthing & LightningChemical Earthing for Lightning ArrestersLow-maintenance chemical earthing for lightning arrester systems.Earthing & LightningLightning Arrester SystemLightning protection to safeguard buildings and equipment.Earthing & LightningEarthing Testing & MaintenanceEarth resistance testing and upkeep of existing earth pits.
Health check

Not sure what you need?

Use the transformer health check for an indicative suggestion.

Transformer age: 10 years
Last oil filtration
Last BDV result
Anything you have noticed?
Moderate attentionSCORE 40/100
SUGGESTED
    Send this check on WhatsApp

    Indicative only — not a test result. An inspection and oil test confirm the actual condition.

    FAQ

    Frequently asked questions

    Anything else? Call or WhatsApp us.

    Ask on WhatsApp

    Transformer oil filtration, transformer repair and maintenance, electrical and oil lab testing, HT/LT panel and substation services, and earthing & lightning protection.

    Yes. We use our own transformer oil filtration machine and test BDV before and after filtration.

    We are based on Sinhgad Road, Pune, and serve Pune, all of Maharashtra and other parts of India.

    Call or WhatsApp +91 77700 05745, or use the work-order form on this website to send your requirement.

    Yes — work is done as per MSEDCL safety standards with PPE, proper isolation and earthing before any testing or oil filtration.

    Pune · Maharashtra · India

    Keep your transformers healthy & online.

    Filtered Reliability, Powered For Tomorrow. Call or WhatsApp for filtration, testing, maintenance or breakdown support.

    Transformer or panel issue? Chat with us