Electrical Testing & Oil Lab Testing

IR, earth resistance, ratio, magnetic balance and winding tests — plus BDV, moisture, DGA, acidity, particle and furan/DDF oil tests.

Electrical Testing & Oil Lab Testing
TESTING & OIL LABSERVICE PLATE
Overview

Testing & Oil Lab done right

Testing tells you what is happening inside equipment you cannot see. We carry out on-site electrical tests on transformers and equipment, and transformer oil lab tests that reveal moisture, ageing and hidden faults.

Results help you plan maintenance before a failure, not after one.

Electrical Testing & Oil Lab Testing
Services

7 services in Testing & Oil Lab

01

Insulation Resistance (IR) Testing

Checks the condition of insulation between windings and to earth.

Enquire
02

Earth Resistance Testing

Measures the resistance of earth pits and earthing systems.

Enquire
03

Transformer Voltage Ratio Testing

Confirms the turns ratio across taps to detect winding faults.

Enquire
04

Magnetic Balance Testing

Checks the balance of the magnetic circuit between phases.

Enquire
05

Winding Resistance Testing

Detects loose connections, broken strands and tap-changer contact problems.

Enquire
06

Electrical Equipment Inspection

Inspection of transformers, panels and equipment with a clear report.

Enquire
07

Transformer Oil Lab Testing

BDV, moisture content, DGA, acidity, particle analysis and furan & DDF tests.

Enquire
Process

How we work

  1. STEP 1

    Plan

    Decide which tests suit your equipment and concern.

  2. STEP 2

    Isolate & sample

    Safe isolation; oil samples drawn correctly.

  3. STEP 3

    Test

    On-site electrical tests and lab oil tests.

  4. STEP 4

    Report & advise

    Results explained with recommended action.

Oil lab tests

Six tests, one clear picture

Tap a test to learn what it reveals.

FAQ

Testing & Oil Lab FAQs

Anything else? Call or WhatsApp us.

Ask on WhatsApp

BDV, moisture content, DGA (dissolved gas analysis), acidity, particle analysis, and furan & DDF tests.

It measures the breakdown voltage of transformer oil — how much voltage the oil can withstand before it fails as an insulator.

Dissolved gas analysis detects developing faults such as overheating or arcing inside the transformer before they cause a breakdown.

Yes, we carry out earth resistance testing and earthing maintenance.

Yes, test results are shared with you along with our recommendations.